bin/netsnmp/mibs/IF-MIB.txt

IF-MIB DEFINITIONS ::= BEGIN
 
IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64,
    Integer32, TimeTicks, mib-2,
    NOTIFICATION-TYPE FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, DisplayString,
    PhysAddress, TruthValue, RowStatus,
    TimeStamp, AutonomousType, TestAndIncr FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP,
    NOTIFICATION-GROUP FROM SNMPv2-CONF
    snmpTraps FROM SNMPv2-MIB
    IANAifType FROM IANAifType-MIB;
 
ifMIB MODULE-IDENTITY
    LAST-UPDATED "200006140000Z"
    ORGANIZATION "IETF Interfaces MIB Working Group"
    CONTACT-INFO
            " Keith McCloghrie
                Cisco Systems, Inc.
                170 West Tasman Drive
                San Jose, CA 95134-1706
                US
 
                408-526-5260
                kzm@cisco.com"
    DESCRIPTION
            "The MIB module to describe generic objects for network
            interface sub-layers. This MIB is an updated version of
            MIB-II's ifTable, and incorporates the extensions defined in
            RFC 1229."
 
    REVISION "200006140000Z"
    DESCRIPTION
            "Clarifications agreed upon by the Interfaces MIB WG, and
            published as RFC 2863."
    REVISION "199602282155Z"
    DESCRIPTION
            "Revisions made by the Interfaces MIB WG, and published in
            RFC 2233."
    REVISION "199311082155Z"
    DESCRIPTION
            "Initial revision, published as part of RFC 1573."
    ::= { mib-2 31 }
 
ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }
 
interfaces OBJECT IDENTIFIER ::= { mib-2 2 }
 
--
-- Textual Conventions
--
 
-- OwnerString has the same semantics as used in RFC 1271
 
OwnerString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS deprecated
    DESCRIPTION
            "This data type is used to model an administratively
            assigned name of the owner of a resource. This information
            is taken from the NVT ASCII character set. It is suggested
            that this name contain one or more of the following: ASCII
            form of the manager station's transport address, management
            station name (e.g., domain name), network management
            personnel's name, location, or phone number. In some cases
            the agent itself will be the owner of an entry. In these
            cases, this string shall be set to a string starting with
            'agent'."
    SYNTAX OCTET STRING (SIZE(0..255))
 
-- InterfaceIndex contains the semantics of ifIndex and should be used
-- for any objects defined in other MIB modules that need these semantics.
 
InterfaceIndex ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS current
    DESCRIPTION
            "A unique value, greater than zero, for each interface or
            interface sub-layer in the managed system. It is
            recommended that values are assigned contiguously starting
            from 1. The value for each interface sub-layer must remain
            constant at least from one re-initialization of the entity's
            network management system to the next re-initialization."
    SYNTAX Integer32 (1..2147483647)
 
InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS current
    DESCRIPTION
            "This textual convention is an extension of the
            InterfaceIndex convention. The latter defines a greater
            than zero value used to identify an interface or interface
            sub-layer in the managed system. This extension permits the
            additional value of zero. the value zero is object-specific
            and must therefore be defined as part of the description of
            any object which uses this syntax. Examples of the usage of
            zero might include situations where interface was unknown,
            or when none or all interfaces need to be referenced."
    SYNTAX Integer32 (0..2147483647)
 
ifNumber OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of network interfaces (regardless of their
            current state) present on this system."
    ::= { interfaces 1 }
 
ifTableLastChange OBJECT-TYPE
    SYNTAX TimeTicks
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The value of sysUpTime at the time of the last creation or
            deletion of an entry in the ifTable. If the number of
            entries has been unchanged since the last re-initialization
            of the local network management subsystem, then this object
            contains a zero value."
    ::= { ifMIBObjects 5 }
 
-- the Interfaces table
 
-- The Interfaces table contains information on the entity's
 
-- interfaces. Each sub-layer below the internetwork-layer
-- of a network interface is considered to be an interface.
 
ifTable OBJECT-TYPE
    SYNTAX SEQUENCE OF IfEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "A list of interface entries. The number of entries is
            given by the value of ifNumber."
    ::= { interfaces 2 }
 
ifEntry OBJECT-TYPE
    SYNTAX IfEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "An entry containing management information applicable to a
            particular interface."
    INDEX { ifIndex }
    ::= { ifTable 1 }
 
IfEntry ::=
    SEQUENCE {
        ifIndex InterfaceIndex,
        ifDescr DisplayString,
        ifType IANAifType,
        ifMtu Integer32,
        ifSpeed Gauge32,
        ifPhysAddress PhysAddress,
        ifAdminStatus INTEGER,
        ifOperStatus INTEGER,
        ifLastChange TimeTicks,
        ifInOctets Counter32,
        ifInUcastPkts Counter32,
        ifInNUcastPkts Counter32, -- deprecated
        ifInDiscards Counter32,
        ifInErrors Counter32,
        ifInUnknownProtos Counter32,
        ifOutOctets Counter32,
        ifOutUcastPkts Counter32,
        ifOutNUcastPkts Counter32, -- deprecated
        ifOutDiscards Counter32,
        ifOutErrors Counter32,
        ifOutQLen Gauge32, -- deprecated
        ifSpecific OBJECT IDENTIFIER -- deprecated
    }
 
ifIndex OBJECT-TYPE
    SYNTAX InterfaceIndex
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "A unique value, greater than zero, for each interface. It
            is recommended that values are assigned contiguously
            starting from 1. The value for each interface sub-layer
            must remain constant at least from one re-initialization of
            the entity's network management system to the next re-
            initialization."
    ::= { ifEntry 1 }
 
ifDescr OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..255))
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "A textual string containing information about the
            interface. This string should include the name of the
            manufacturer, the product name and the version of the
            interface hardware/software."
    ::= { ifEntry 2 }
 
ifType OBJECT-TYPE
    SYNTAX IANAifType
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The type of interface. Additional values for ifType are
            assigned by the Internet Assigned Numbers Authority (IANA),
            through updating the syntax of the IANAifType textual
            convention."
    ::= { ifEntry 3 }
 
ifMtu OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The size of the largest packet which can be sent/received
            on the interface, specified in octets. For interfaces that
            are used for transmitting network datagrams, this is the
            size of the largest network datagram that can be sent on the
            interface."
    ::= { ifEntry 4 }
 
ifSpeed OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "An estimate of the interface's current bandwidth in bits
            per second. For interfaces which do not vary in bandwidth
            or for those where no accurate estimation can be made, this
            object should contain the nominal bandwidth. If the
            bandwidth of the interface is greater than the maximum value
            reportable by this object then this object should report its
            maximum value (4,294,967,295) and ifHighSpeed must be used
            to report the interace's speed. For a sub-layer which has
            no concept of bandwidth, this object should be zero."
    ::= { ifEntry 5 }
 
ifPhysAddress OBJECT-TYPE
    SYNTAX PhysAddress
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The interface's address at its protocol sub-layer. For
            example, for an 802.x interface, this object normally
            contains a MAC address. The interface's media-specific MIB
            must define the bit and byte ordering and the format of the
            value of this object. For interfaces which do not have such
            an address (e.g., a serial line), this object should contain
            an octet string of zero length."
    ::= { ifEntry 6 }
 
ifAdminStatus OBJECT-TYPE
    SYNTAX INTEGER {
                up(1), -- ready to pass packets
                down(2),
                testing(3) -- in some test mode
            }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
            "The desired state of the interface. The testing(3) state
            indicates that no operational packets can be passed. When a
            managed system initializes, all interfaces start with
            ifAdminStatus in the down(2) state. As a result of either
            explicit management action or per configuration information
            retained by the managed system, ifAdminStatus is then
            changed to either the up(1) or testing(3) states (or remains
            in the down(2) state)."
    ::= { ifEntry 7 }
 
ifOperStatus OBJECT-TYPE
    SYNTAX INTEGER {
                up(1), -- ready to pass packets
                down(2),
                testing(3), -- in some test mode
                unknown(4), -- status can not be determined
                              -- for some reason.
                dormant(5),
                notPresent(6), -- some component is missing
                lowerLayerDown(7) -- down due to state of
                                  -- lower-layer interface(s)
            }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The current operational state of the interface. The
            testing(3) state indicates that no operational packets can
            be passed. If ifAdminStatus is down(2) then ifOperStatus
            should be down(2). If ifAdminStatus is changed to up(1)
            then ifOperStatus should change to up(1) if the interface is
            ready to transmit and receive network traffic; it should
            change to dormant(5) if the interface is waiting for
            external actions (such as a serial line waiting for an
            incoming connection); it should remain in the down(2) state
            if and only if there is a fault that prevents it from going
            to the up(1) state; it should remain in the notPresent(6)
            state if the interface has missing (typically, hardware)
            components."
    ::= { ifEntry 8 }
 
ifLastChange OBJECT-TYPE
    SYNTAX TimeTicks
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The value of sysUpTime at the time the interface entered
            its current operational state. If the current state was
            entered prior to the last re-initialization of the local
            network management subsystem, then this object contains a
            zero value."
    ::= { ifEntry 9 }
 
ifInOctets OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of octets received on the interface,
            including framing characters.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 10 }
 
ifInUcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were not addressed to a multicast
            or broadcast address at this sub-layer.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 11 }
 
ifInNUcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a multicast or
            broadcast address at this sub-layer.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime.
 
            This object is deprecated in favour of ifInMulticastPkts and
            ifInBroadcastPkts."
    ::= { ifEntry 12 }
 
ifInDiscards OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of inbound packets which were chosen to be
            discarded even though no errors had been detected to prevent
 
            their being deliverable to a higher-layer protocol. One
            possible reason for discarding such a packet could be to
            free up buffer space.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 13 }
 
ifInErrors OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "For packet-oriented interfaces, the number of inbound
            packets that contained errors preventing them from being
            deliverable to a higher-layer protocol. For character-
            oriented or fixed-length interfaces, the number of inbound
            transmission units that contained errors preventing them
            from being deliverable to a higher-layer protocol.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 14 }
 
ifInUnknownProtos OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "For packet-oriented interfaces, the number of packets
            received via the interface which were discarded because of
            an unknown or unsupported protocol. For character-oriented
            or fixed-length interfaces that support protocol
            multiplexing the number of transmission units received via
            the interface which were discarded because of an unknown or
            unsupported protocol. For any interface that does not
            support protocol multiplexing, this counter will always be
            0.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 15 }
 
ifOutOctets OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of octets transmitted out of the
            interface, including framing characters.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 16 }
 
ifOutUcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were not addressed to a
            multicast or broadcast address at this sub-layer, including
            those that were discarded or not sent.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 17 }
 
ifOutNUcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            multicast or broadcast address at this sub-layer, including
            those that were discarded or not sent.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime.
 
            This object is deprecated in favour of ifOutMulticastPkts
            and ifOutBroadcastPkts."
    ::= { ifEntry 18 }
 
ifOutDiscards OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of outbound packets which were chosen to be
            discarded even though no errors had been detected to prevent
            their being transmitted. One possible reason for discarding
            such a packet could be to free up buffer space.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 19 }
 
ifOutErrors OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "For packet-oriented interfaces, the number of outbound
            packets that could not be transmitted because of errors.
            For character-oriented or fixed-length interfaces, the
            number of outbound transmission units that could not be
            transmitted because of errors.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifEntry 20 }
 
ifOutQLen OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "The length of the output packet queue (in packets)."
    ::= { ifEntry 21 }
 
ifSpecific OBJECT-TYPE
    SYNTAX OBJECT IDENTIFIER
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "A reference to MIB definitions specific to the particular
            media being used to realize the interface. It is
 
            recommended that this value point to an instance of a MIB
            object in the media-specific MIB, i.e., that this object
            have the semantics associated with the InstancePointer
            textual convention defined in RFC 2579. In fact, it is
            recommended that the media-specific MIB specify what value
            ifSpecific should/can take for values of ifType. If no MIB
            definitions specific to the particular media are available,
            the value should be set to the OBJECT IDENTIFIER { 0 0 }."
    ::= { ifEntry 22 }
 
--
-- Extension to the interface table
--
-- This table replaces the ifExtnsTable table.
--
 
ifXTable OBJECT-TYPE
    SYNTAX SEQUENCE OF IfXEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "A list of interface entries. The number of entries is
            given by the value of ifNumber. This table contains
            additional objects for the interface table."
    ::= { ifMIBObjects 1 }
 
ifXEntry OBJECT-TYPE
    SYNTAX IfXEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "An entry containing additional management information
            applicable to a particular interface."
    AUGMENTS { ifEntry }
    ::= { ifXTable 1 }
 
IfXEntry ::=
    SEQUENCE {
        ifName DisplayString,
        ifInMulticastPkts Counter32,
        ifInBroadcastPkts Counter32,
        ifOutMulticastPkts Counter32,
        ifOutBroadcastPkts Counter32,
        ifHCInOctets Counter64,
        ifHCInUcastPkts Counter64,
        ifHCInMulticastPkts Counter64,
        ifHCInBroadcastPkts Counter64,
        ifHCOutOctets Counter64,
        ifHCOutUcastPkts Counter64,
        ifHCOutMulticastPkts Counter64,
        ifHCOutBroadcastPkts Counter64,
        ifLinkUpDownTrapEnable INTEGER,
        ifHighSpeed Gauge32,
        ifPromiscuousMode TruthValue,
        ifConnectorPresent TruthValue,
        ifAlias DisplayString,
        ifCounterDiscontinuityTime TimeStamp
    }
 
ifName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The textual name of the interface. The value of this
            object should be the name of the interface as assigned by
            the local device and should be suitable for use in commands
            entered at the device's `console'. This might be a text
            name, such as `le0' or a simple port number, such as `1',
            depending on the interface naming syntax of the device. If
            several entries in the ifTable together represent a single
            interface as named by the device, then each will have the
            same value of ifName. Note that for an agent which responds
            to SNMP queries concerning an interface on some other
            (proxied) device, then the value of ifName for such an
            interface is the proxied device's local name for it.
 
            If there is no local name, or this object is otherwise not
            applicable, then this object contains a zero-length string."
    ::= { ifXEntry 1 }
 
ifInMulticastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a multicast
            address at this sub-layer. For a MAC layer protocol, this
            includes both Group and Functional addresses.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
 
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 2 }
 
ifInBroadcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a broadcast
            address at this sub-layer.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 3 }
 
ifOutMulticastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            multicast address at this sub-layer, including those that
            were discarded or not sent. For a MAC layer protocol, this
            includes both Group and Functional addresses.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 4 }
 
ifOutBroadcastPkts OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            broadcast address at this sub-layer, including those that
            were discarded or not sent.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
 
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 5 }
 
--
-- High Capacity Counter objects. These objects are all
-- 64 bit versions of the "basic" ifTable counters. These
-- objects all have the same basic semantics as their 32-bit
-- counterparts, however, their syntax has been extended
-- to 64 bits.
--
 
ifHCInOctets OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of octets received on the interface,
            including framing characters. This object is a 64-bit
            version of ifInOctets.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 6 }
 
ifHCInUcastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were not addressed to a multicast
            or broadcast address at this sub-layer. This object is a
            64-bit version of ifInUcastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 7 }
 
ifHCInMulticastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a multicast
            address at this sub-layer. For a MAC layer protocol, this
            includes both Group and Functional addresses. This object
            is a 64-bit version of ifInMulticastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 8 }
 
ifHCInBroadcastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The number of packets, delivered by this sub-layer to a
            higher (sub-)layer, which were addressed to a broadcast
            address at this sub-layer. This object is a 64-bit version
            of ifInBroadcastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 9 }
 
ifHCOutOctets OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of octets transmitted out of the
            interface, including framing characters. This object is a
            64-bit version of ifOutOctets.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 10 }
 
ifHCOutUcastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were not addressed to a
            multicast or broadcast address at this sub-layer, including
            those that were discarded or not sent. This object is a
            64-bit version of ifOutUcastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 11 }
 
ifHCOutMulticastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            multicast address at this sub-layer, including those that
            were discarded or not sent. For a MAC layer protocol, this
            includes both Group and Functional addresses. This object
            is a 64-bit version of ifOutMulticastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 12 }
 
ifHCOutBroadcastPkts OBJECT-TYPE
    SYNTAX Counter64
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The total number of packets that higher-level protocols
            requested be transmitted, and which were addressed to a
            broadcast address at this sub-layer, including those that
            were discarded or not sent. This object is a 64-bit version
            of ifOutBroadcastPkts.
 
            Discontinuities in the value of this counter can occur at
            re-initialization of the management system, and at other
            times as indicated by the value of
            ifCounterDiscontinuityTime."
    ::= { ifXEntry 13 }
 
ifLinkUpDownTrapEnable OBJECT-TYPE
    SYNTAX INTEGER { enabled(1), disabled(2) }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
            "Indicates whether linkUp/linkDown traps should be generated
            for this interface.
 
            By default, this object should have the value enabled(1) for
            interfaces which do not operate on 'top' of any other
            interface (as defined in the ifStackTable), and disabled(2)
            otherwise."
    ::= { ifXEntry 14 }
 
ifHighSpeed OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "An estimate of the interface's current bandwidth in units
            of 1,000,000 bits per second. If this object reports a
            value of `n' then the speed of the interface is somewhere in
            the range of `n-500,000' to `n+499,999'. For interfaces
            which do not vary in bandwidth or for those where no
            accurate estimation can be made, this object should contain
            the nominal bandwidth. For a sub-layer which has no concept
            of bandwidth, this object should be zero."
    ::= { ifXEntry 15 }
 
ifPromiscuousMode OBJECT-TYPE
    SYNTAX TruthValue
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
            "This object has a value of false(2) if this interface only
            accepts packets/frames that are addressed to this station.
            This object has a value of true(1) when the station accepts
            all packets/frames transmitted on the media. The value
            true(1) is only legal on certain types of media. If legal,
            setting this object to a value of true(1) may require the
            interface to be reset before becoming effective.
 
            The value of ifPromiscuousMode does not affect the reception
            of broadcast and multicast packets/frames by the interface."
    ::= { ifXEntry 16 }
 
ifConnectorPresent OBJECT-TYPE
    SYNTAX TruthValue
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "This object has the value 'true(1)' if the interface
            sublayer has a physical connector and the value 'false(2)'
            otherwise."
    ::= { ifXEntry 17 }
 
ifAlias OBJECT-TYPE
    SYNTAX DisplayString (SIZE(0..64))
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
            "This object is an 'alias' name for the interface as
            specified by a network manager, and provides a non-volatile
            'handle' for the interface.
 
            On the first instantiation of an interface, the value of
            ifAlias associated with that interface is the zero-length
            string. As and when a value is written into an instance of
            ifAlias through a network management set operation, then the
            agent must retain the supplied value in the ifAlias instance
            associated with the same interface for as long as that
            interface remains instantiated, including across all re-
            initializations/reboots of the network management system,
            including those which result in a change of the interface's
            ifIndex value.
 
            An example of the value which a network manager might store
            in this object for a WAN interface is the (Telco's) circuit
            number/identifier of the interface.
 
            Some agents may support write-access only for interfaces
            having particular values of ifType. An agent which supports
            write access to this object is required to keep the value in
            non-volatile storage, but it may limit the length of new
            values depending on how much storage is already occupied by
            the current values for other interfaces."
    ::= { ifXEntry 18 }
 
ifCounterDiscontinuityTime OBJECT-TYPE
    SYNTAX TimeStamp
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The value of sysUpTime on the most recent occasion at which
            any one or more of this interface's counters suffered a
            discontinuity. The relevant counters are the specific
            instances associated with this interface of any Counter32 or
 
            Counter64 object contained in the ifTable or ifXTable. If
            no such discontinuities have occurred since the last re-
            initialization of the local management subsystem, then this
            object contains a zero value."
    ::= { ifXEntry 19 }
 
-- The Interface Stack Group
--
-- Implementation of this group is optional, but strongly recommended
-- for all systems
--
 
ifStackTable OBJECT-TYPE
     SYNTAX SEQUENCE OF IfStackEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
            "The table containing information on the relationships
            between the multiple sub-layers of network interfaces. In
            particular, it contains information on which sub-layers run
            'on top of' which other sub-layers, where each sub-layer
            corresponds to a conceptual row in the ifTable. For
            example, when the sub-layer with ifIndex value x runs over
            the sub-layer with ifIndex value y, then this table
            contains:
 
              ifStackStatus.x.y=active
 
            For each ifIndex value, I, which identifies an active
            interface, there are always at least two instantiated rows
            in this table associated with I. For one of these rows, I
            is the value of ifStackHigherLayer; for the other, I is the
            value of ifStackLowerLayer. (If I is not involved in
            multiplexing, then these are the only two rows associated
            with I.)
 
            For example, two rows exist even for an interface which has
            no others stacked on top or below it:
 
              ifStackStatus.0.x=active
              ifStackStatus.x.0=active "
     ::= { ifMIBObjects 2 }
 
ifStackEntry OBJECT-TYPE
     SYNTAX IfStackEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
            "Information on a particular relationship between two sub-
            layers, specifying that one sub-layer runs on 'top' of the
            other sub-layer. Each sub-layer corresponds to a conceptual
            row in the ifTable."
     INDEX { ifStackHigherLayer, ifStackLowerLayer }
     ::= { ifStackTable 1 }
 
IfStackEntry ::=
    SEQUENCE {
        ifStackHigherLayer InterfaceIndexOrZero,
        ifStackLowerLayer InterfaceIndexOrZero,
        ifStackStatus RowStatus
     }
 
ifStackHigherLayer OBJECT-TYPE
     SYNTAX InterfaceIndexOrZero
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
            "The value of ifIndex corresponding to the higher sub-layer
            of the relationship, i.e., the sub-layer which runs on 'top'
            of the sub-layer identified by the corresponding instance of
            ifStackLowerLayer. If there is no higher sub-layer (below
            the internetwork layer), then this object has the value 0."
     ::= { ifStackEntry 1 }
 
ifStackLowerLayer OBJECT-TYPE
     SYNTAX InterfaceIndexOrZero
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
            "The value of ifIndex corresponding to the lower sub-layer
            of the relationship, i.e., the sub-layer which runs 'below'
            the sub-layer identified by the corresponding instance of
            ifStackHigherLayer. If there is no lower sub-layer, then
            this object has the value 0."
     ::= { ifStackEntry 2 }
 
ifStackStatus OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
            "The status of the relationship between two sub-layers.
 
            Changing the value of this object from 'active' to
            'notInService' or 'destroy' will likely have consequences up
            and down the interface stack. Thus, write access to this
            object is likely to be inappropriate for some types of
            interfaces, and many implementations will choose not to
            support write-access for any type of interface."
    ::= { ifStackEntry 3 }
 
ifStackLastChange OBJECT-TYPE
    SYNTAX TimeTicks
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
            "The value of sysUpTime at the time of the last change of
            the (whole) interface stack. A change of the interface
            stack is defined to be any creation, deletion, or change in
            value of any instance of ifStackStatus. If the interface
            stack has been unchanged since the last re-initialization of
            the local network management subsystem, then this object
            contains a zero value."
    ::= { ifMIBObjects 6 }
 
-- Generic Receive Address Table
--
-- This group of objects is mandatory for all types of
-- interfaces which can receive packets/frames addressed to
-- more than one address.
--
-- This table replaces the ifExtnsRcvAddr table. The main
-- difference is that this table makes use of the RowStatus
-- textual convention, while ifExtnsRcvAddr did not.
 
ifRcvAddressTable OBJECT-TYPE
    SYNTAX SEQUENCE OF IfRcvAddressEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "This table contains an entry for each address (broadcast,
            multicast, or uni-cast) for which the system will receive
            packets/frames on a particular interface, except as follows:
 
            - for an interface operating in promiscuous mode, entries
            are only required for those addresses for which the system
            would receive frames were it not operating in promiscuous
            mode.
 
            - for 802.5 functional addresses, only one entry is
            required, for the address which has the functional address
            bit ANDed with the bit mask of all functional addresses for
            which the interface will accept frames.
 
            A system is normally able to use any unicast address which
            corresponds to an entry in this table as a source address."
    ::= { ifMIBObjects 4 }
 
ifRcvAddressEntry OBJECT-TYPE
    SYNTAX IfRcvAddressEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "A list of objects identifying an address for which the
            system will accept packets/frames on the particular
            interface identified by the index value ifIndex."
    INDEX { ifIndex, ifRcvAddressAddress }
    ::= { ifRcvAddressTable 1 }
 
IfRcvAddressEntry ::=
    SEQUENCE {
        ifRcvAddressAddress PhysAddress,
        ifRcvAddressStatus RowStatus,
        ifRcvAddressType INTEGER
    }
 
ifRcvAddressAddress OBJECT-TYPE
    SYNTAX PhysAddress
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
            "An address for which the system will accept packets/frames
            on this entry's interface."
    ::= { ifRcvAddressEntry 1 }
 
ifRcvAddressStatus OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
            "This object is used to create and delete rows in the
            ifRcvAddressTable."
    ::= { ifRcvAddressEntry 2 }
 
ifRcvAddressType OBJECT-TYPE
    SYNTAX INTEGER {
 
                    other(1),
                    volatile(2),
                    nonVolatile(3)
                }
    MAX-ACCESS read-create
    STATUS current
    DESCRIPTION
            "This object has the value nonVolatile(3) for those entries
            in the table which are valid and will not be deleted by the
            next restart of the managed system. Entries having the
            value volatile(2) are valid and exist, but have not been
            saved, so that will not exist after the next restart of the
            managed system. Entries having the value other(1) are valid
            and exist but are not classified as to whether they will
            continue to exist after the next restart."
    DEFVAL { volatile }
    ::= { ifRcvAddressEntry 3 }
 
-- definition of interface-related traps.
 
linkDown NOTIFICATION-TYPE
    OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
    STATUS current
    DESCRIPTION
            "A linkDown trap signifies that the SNMP entity, acting in
            an agent role, has detected that the ifOperStatus object for
            one of its communication links is about to enter the down
            state from some other state (but not from the notPresent
            state). This other state is indicated by the included value
            of ifOperStatus."
    ::= { snmpTraps 3 }
 
linkUp NOTIFICATION-TYPE
    OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
    STATUS current
    DESCRIPTION
            "A linkUp trap signifies that the SNMP entity, acting in an
            agent role, has detected that the ifOperStatus object for
            one of its communication links left the down state and
            transitioned into some other state (but not into the
            notPresent state). This other state is indicated by the
            included value of ifOperStatus."
    ::= { snmpTraps 4 }
 
-- conformance information
 
ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 }
 
ifGroups OBJECT IDENTIFIER ::= { ifConformance 1 }
ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 }
 
-- compliance statements
 
ifCompliance3 MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
            "The compliance statement for SNMP entities which have
            network interfaces."
 
    MODULE -- this module
        MANDATORY-GROUPS { ifGeneralInformationGroup,
                           linkUpDownNotificationsGroup }
 
-- The groups:
-- ifFixedLengthGroup
-- ifHCFixedLengthGroup
-- ifPacketGroup
-- ifHCPacketGroup
-- ifVHCPacketGroup
-- are mutually exclusive; at most one of these groups is implemented
-- for a particular interface. When any of these groups is implemented
-- for a particular interface, then ifCounterDiscontinuityGroup must
-- also be implemented for that interface.
 
        GROUP ifFixedLengthGroup
        DESCRIPTION
            "This group is mandatory for those network interfaces which
            are character-oriented or transmit data in fixed-length
            transmission units, and for which the value of the
            corresponding instance of ifSpeed is less than or equal to
            20,000,000 bits/second."
 
        GROUP ifHCFixedLengthGroup
        DESCRIPTION
            "This group is mandatory for those network interfaces which
            are character-oriented or transmit data in fixed-length
            transmission units, and for which the value of the
            corresponding instance of ifSpeed is greater than 20,000,000
            bits/second."
 
        GROUP ifPacketGroup
        DESCRIPTION
            "This group is mandatory for those network interfaces which
            are packet-oriented, and for which the value of the
            corresponding instance of ifSpeed is less than or equal to
            20,000,000 bits/second."
 
        GROUP ifHCPacketGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are packet-oriented and for which the value of the
            corresponding instance of ifSpeed is greater than 20,000,000
            bits/second but less than or equal to 650,000,000
            bits/second."
 
        GROUP ifVHCPacketGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are packet-oriented and for which the value of the
            corresponding instance of ifSpeed is greater than
            650,000,000 bits/second."
 
        GROUP ifCounterDiscontinuityGroup
        DESCRIPTION
            "This group is mandatory for those network interfaces that
            are required to maintain counters (i.e., those for which one
            of the ifFixedLengthGroup, ifHCFixedLengthGroup,
            ifPacketGroup, ifHCPacketGroup, or ifVHCPacketGroup is
            mandatory)."
 
        GROUP ifRcvAddressGroup
        DESCRIPTION
            "The applicability of this group MUST be defined by the
            media-specific MIBs. Media-specific MIBs must define the
            exact meaning, use, and semantics of the addresses in this
            group."
 
        OBJECT ifLinkUpDownTrapEnable
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifPromiscuousMode
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifAdminStatus
        SYNTAX INTEGER { up(1), down(2) }
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required, nor is support for the value
            testing(3)."
 
        OBJECT ifAlias
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
    ::= { ifCompliances 3 }
 
-- units of conformance
 
ifGeneralInformationGroup OBJECT-GROUP
    OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress,
              ifAdminStatus, ifOperStatus, ifLastChange,
              ifLinkUpDownTrapEnable, ifConnectorPresent,
              ifHighSpeed, ifName, ifNumber, ifAlias,
              ifTableLastChange }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information applicable to
            all network interfaces."
    ::= { ifGroups 10 }
 
-- the following five groups are mutually exclusive; at most
-- one of these groups is implemented for any interface
 
ifFixedLengthGroup OBJECT-GROUP
    OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
              ifInErrors, ifOutErrors }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            non-high speed (non-high speed interfaces transmit and
            receive at speeds less than or equal to 20,000,000
            bits/second) character-oriented or fixed-length-transmission
            network interfaces."
    ::= { ifGroups 2 }
 
ifHCFixedLengthGroup OBJECT-GROUP
    OBJECTS { ifHCInOctets, ifHCOutOctets,
              ifInOctets, ifOutOctets, ifInUnknownProtos,
              ifInErrors, ifOutErrors }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            high speed (greater than 20,000,000 bits/second) character-
            oriented or fixed-length-transmission network interfaces."
    ::= { ifGroups 3 }
 
ifPacketGroup OBJECT-GROUP
    OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
              ifInErrors, ifOutErrors,
              ifMtu, ifInUcastPkts, ifInMulticastPkts,
              ifInBroadcastPkts, ifInDiscards,
              ifOutUcastPkts, ifOutMulticastPkts,
              ifOutBroadcastPkts, ifOutDiscards,
              ifPromiscuousMode }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            non-high speed (non-high speed interfaces transmit and
            receive at speeds less than or equal to 20,000,000
            bits/second) packet-oriented network interfaces."
    ::= { ifGroups 4 }
 
ifHCPacketGroup OBJECT-GROUP
    OBJECTS { ifHCInOctets, ifHCOutOctets,
              ifInOctets, ifOutOctets, ifInUnknownProtos,
              ifInErrors, ifOutErrors,
              ifMtu, ifInUcastPkts, ifInMulticastPkts,
              ifInBroadcastPkts, ifInDiscards,
              ifOutUcastPkts, ifOutMulticastPkts,
              ifOutBroadcastPkts, ifOutDiscards,
              ifPromiscuousMode }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            high speed (greater than 20,000,000 bits/second but less
            than or equal to 650,000,000 bits/second) packet-oriented
            network interfaces."
    ::= { ifGroups 5 }
 
ifVHCPacketGroup OBJECT-GROUP
    OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts,
              ifHCInBroadcastPkts, ifHCOutUcastPkts,
              ifHCOutMulticastPkts, ifHCOutBroadcastPkts,
              ifHCInOctets, ifHCOutOctets,
              ifInOctets, ifOutOctets, ifInUnknownProtos,
              ifInErrors, ifOutErrors,
              ifMtu, ifInUcastPkts, ifInMulticastPkts,
              ifInBroadcastPkts, ifInDiscards,
              ifOutUcastPkts, ifOutMulticastPkts,
              ifOutBroadcastPkts, ifOutDiscards,
              ifPromiscuousMode }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            higher speed (greater than 650,000,000 bits/second) packet-
            oriented network interfaces."
    ::= { ifGroups 6 }
 
ifRcvAddressGroup OBJECT-GROUP
    OBJECTS { ifRcvAddressStatus, ifRcvAddressType }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information on the
            multiple addresses which an interface receives."
    ::= { ifGroups 7 }
 
ifStackGroup2 OBJECT-GROUP
    OBJECTS { ifStackStatus, ifStackLastChange }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information on the
            layering of MIB-II interfaces."
    ::= { ifGroups 11 }
 
ifCounterDiscontinuityGroup OBJECT-GROUP
    OBJECTS { ifCounterDiscontinuityTime }
    STATUS current
    DESCRIPTION
            "A collection of objects providing information specific to
            interface counter discontinuities."
    ::= { ifGroups 13 }
 
linkUpDownNotificationsGroup NOTIFICATION-GROUP
    NOTIFICATIONS { linkUp, linkDown }
    STATUS current
    DESCRIPTION
            "The notifications which indicate specific changes in the
            value of ifOperStatus."
    ::= { ifGroups 14 }
 
-- Deprecated Definitions - Objects
 
--
-- The Interface Test Table
--
-- This group of objects is optional. However, a media-specific
 
-- MIB may make implementation of this group mandatory.
--
-- This table replaces the ifExtnsTestTable
--
 
ifTestTable OBJECT-TYPE
    SYNTAX SEQUENCE OF IfTestEntry
    MAX-ACCESS not-accessible
    STATUS deprecated
    DESCRIPTION
            "This table contains one entry per interface. It defines
            objects which allow a network manager to instruct an agent
            to test an interface for various faults. Tests for an
            interface are defined in the media-specific MIB for that
            interface. After invoking a test, the object ifTestResult
            can be read to determine the outcome. If an agent can not
            perform the test, ifTestResult is set to so indicate. The
            object ifTestCode can be used to provide further test-
            specific or interface-specific (or even enterprise-specific)
            information concerning the outcome of the test. Only one
            test can be in progress on each interface at any one time.
            If one test is in progress when another test is invoked, the
            second test is rejected. Some agents may reject a test when
            a prior test is active on another interface.
 
            Before starting a test, a manager-station must first obtain
            'ownership' of the entry in the ifTestTable for the
            interface to be tested. This is accomplished with the
            ifTestId and ifTestStatus objects as follows:
 
          try_again:
              get (ifTestId, ifTestStatus)
              while (ifTestStatus != notInUse)
                  /*
                   * Loop while a test is running or some other
                   * manager is configuring a test.
                   */
                  short delay
                  get (ifTestId, ifTestStatus)
              }
 
              /*
               * Is not being used right now -- let's compete
               * to see who gets it.
               */
              lock_value = ifTestId
 
              if ( set(ifTestId = lock_value, ifTestStatus = inUse,
                       ifTestOwner = 'my-IP-address') == FAILURE)
                  /*
                   * Another manager got the ifTestEntry -- go
                   * try again
                   */
                  goto try_again;
 
              /*
               * I have the lock
               */
              set up any test parameters.
 
              /*
               * This starts the test
               */
              set(ifTestType = test_to_run);
 
              wait for test completion by polling ifTestResult
 
              when test completes, agent sets ifTestResult
                   agent also sets ifTestStatus = 'notInUse'
 
              retrieve any additional test results, and ifTestId
 
              if (ifTestId == lock_value+1) results are valid
 
            A manager station first retrieves the value of the
            appropriate ifTestId and ifTestStatus objects, periodically
            repeating the retrieval if necessary, until the value of
            ifTestStatus is 'notInUse'. The manager station then tries
            to set the same ifTestId object to the value it just
            retrieved, the same ifTestStatus object to 'inUse', and the
            corresponding ifTestOwner object to a value indicating
            itself. If the set operation succeeds then the manager has
            obtained ownership of the ifTestEntry, and the value of the
            ifTestId object is incremented by the agent (per the
            semantics of TestAndIncr). Failure of the set operation
            indicates that some other manager has obtained ownership of
            the ifTestEntry.
 
            Once ownership is obtained, any test parameters can be
            setup, and then the test is initiated by setting ifTestType.
            On completion of the test, the agent sets ifTestStatus to
            'notInUse'. Once this occurs, the manager can retrieve the
            results. In the (rare) event that the invocation of tests
            by two network managers were to overlap, then there would be
            a possibility that the first test's results might be
            overwritten by the second test's results prior to the first
 
            results being read. This unlikely circumstance can be
            detected by a network manager retrieving ifTestId at the
            same time as retrieving the test results, and ensuring that
            the results are for the desired request.
 
            If ifTestType is not set within an abnormally long period of
            time after ownership is obtained, the agent should time-out
            the manager, and reset the value of the ifTestStatus object
            back to 'notInUse'. It is suggested that this time-out
            period be 5 minutes.
 
            In general, a management station must not retransmit a
            request to invoke a test for which it does not receive a
            response; instead, it properly inspects an agent's MIB to
            determine if the invocation was successful. Only if the
            invocation was unsuccessful, is the invocation request
            retransmitted.
 
            Some tests may require the interface to be taken off-line in
            order to execute them, or may even require the agent to
            reboot after completion of the test. In these
            circumstances, communication with the management station
            invoking the test may be lost until after completion of the
            test. An agent is not required to support such tests.
            However, if such tests are supported, then the agent should
            make every effort to transmit a response to the request
            which invoked the test prior to losing communication. When
            the agent is restored to normal service, the results of the
            test are properly made available in the appropriate objects.
            Note that this requires that the ifIndex value assigned to
            an interface must be unchanged even if the test causes a
            reboot. An agent must reject any test for which it cannot,
            perhaps due to resource constraints, make available at least
            the minimum amount of information after that test
            completes."
    ::= { ifMIBObjects 3 }
 
ifTestEntry OBJECT-TYPE
    SYNTAX IfTestEntry
    MAX-ACCESS not-accessible
    STATUS deprecated
    DESCRIPTION
            "An entry containing objects for invoking tests on an
            interface."
    AUGMENTS { ifEntry }
    ::= { ifTestTable 1 }
 
IfTestEntry ::=
 
    SEQUENCE {
        ifTestId TestAndIncr,
        ifTestStatus INTEGER,
        ifTestType AutonomousType,
        ifTestResult INTEGER,
        ifTestCode OBJECT IDENTIFIER,
        ifTestOwner OwnerString
    }
 
ifTestId OBJECT-TYPE
    SYNTAX TestAndIncr
    MAX-ACCESS read-write
    STATUS deprecated
    DESCRIPTION
            "This object identifies the current invocation of the
            interface's test."
    ::= { ifTestEntry 1 }
 
ifTestStatus OBJECT-TYPE
    SYNTAX INTEGER { notInUse(1), inUse(2) }
    MAX-ACCESS read-write
    STATUS deprecated
    DESCRIPTION
            "This object indicates whether or not some manager currently
            has the necessary 'ownership' required to invoke a test on
            this interface. A write to this object is only successful
            when it changes its value from 'notInUse(1)' to 'inUse(2)'.
            After completion of a test, the agent resets the value back
            to 'notInUse(1)'."
    ::= { ifTestEntry 2 }
 
ifTestType OBJECT-TYPE
    SYNTAX AutonomousType
    MAX-ACCESS read-write
    STATUS deprecated
    DESCRIPTION
            "A control variable used to start and stop operator-
            initiated interface tests. Most OBJECT IDENTIFIER values
            assigned to tests are defined elsewhere, in association with
            specific types of interface. However, this document assigns
            a value for a full-duplex loopback test, and defines the
            special meanings of the subject identifier:
 
                noTest OBJECT IDENTIFIER ::= { 0 0 }
 
            When the value noTest is written to this object, no action
            is taken unless a test is in progress, in which case the
            test is aborted. Writing any other value to this object is
 
            only valid when no test is currently in progress, in which
            case the indicated test is initiated.
 
            When read, this object always returns the most recent value
            that ifTestType was set to. If it has not been set since
            the last initialization of the network management subsystem
            on the agent, a value of noTest is returned."
    ::= { ifTestEntry 3 }
 
ifTestResult OBJECT-TYPE
    SYNTAX INTEGER {
                     none(1), -- no test yet requested
                     success(2),
                     inProgress(3),
                     notSupported(4),
                     unAbleToRun(5), -- due to state of system
                     aborted(6),
                     failed(7)
                 }
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "This object contains the result of the most recently
            requested test, or the value none(1) if no tests have been
            requested since the last reset. Note that this facility
            provides no provision for saving the results of one test
            when starting another, as could be required if used by
            multiple managers concurrently."
    ::= { ifTestEntry 4 }
 
ifTestCode OBJECT-TYPE
    SYNTAX OBJECT IDENTIFIER
    MAX-ACCESS read-only
    STATUS deprecated
    DESCRIPTION
            "This object contains a code which contains more specific
            information on the test result, for example an error-code
            after a failed test. Error codes and other values this
            object may take are specific to the type of interface and/or
            test. The value may have the semantics of either the
            AutonomousType or InstancePointer textual conventions as
            defined in RFC 2579. The identifier:
 
                testCodeUnknown OBJECT IDENTIFIER ::= { 0 0 }
 
            is defined for use if no additional result code is
            available."
    ::= { ifTestEntry 5 }
 
ifTestOwner OBJECT-TYPE
    SYNTAX OwnerString
    MAX-ACCESS read-write
    STATUS deprecated
    DESCRIPTION
            "The entity which currently has the 'ownership' required to
            invoke a test on this interface."
    ::= { ifTestEntry 6 }
 
-- Deprecated Definitions - Groups
 
ifGeneralGroup OBJECT-GROUP
    OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress,
              ifAdminStatus, ifOperStatus, ifLastChange,
              ifLinkUpDownTrapEnable, ifConnectorPresent,
              ifHighSpeed, ifName }
    STATUS deprecated
    DESCRIPTION
            "A collection of objects deprecated in favour of
            ifGeneralInformationGroup."
    ::= { ifGroups 1 }
 
ifTestGroup OBJECT-GROUP
    OBJECTS { ifTestId, ifTestStatus, ifTestType,
              ifTestResult, ifTestCode, ifTestOwner }
    STATUS deprecated
    DESCRIPTION
            "A collection of objects providing the ability to invoke
            tests on an interface."
    ::= { ifGroups 8 }
 
ifStackGroup OBJECT-GROUP
    OBJECTS { ifStackStatus }
    STATUS deprecated
    DESCRIPTION
            "The previous collection of objects providing information on
            the layering of MIB-II interfaces."
    ::= { ifGroups 9 }
 
ifOldObjectsGroup OBJECT-GROUP
    OBJECTS { ifInNUcastPkts, ifOutNUcastPkts,
              ifOutQLen, ifSpecific }
    STATUS deprecated
    DESCRIPTION
            "The collection of objects deprecated from the original MIB-
            II interfaces group."
    ::= { ifGroups 12 }
 
-- Deprecated Definitions - Compliance
 
ifCompliance MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "A compliance statement defined in a previous version of
            this MIB module, for SNMP entities which have network
            interfaces."
 
    MODULE -- this module
        MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup }
 
        GROUP ifFixedLengthGroup
        DESCRIPTION
            "This group is mandatory for all network interfaces which
            are character-oriented or transmit data in fixed-length
            transmission units."
 
        GROUP ifHCFixedLengthGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are character-oriented or transmit data in fixed-
            length transmission units, and for which the value of the
            corresponding instance of ifSpeed is greater than 20,000,000
            bits/second."
 
        GROUP ifPacketGroup
        DESCRIPTION
            "This group is mandatory for all network interfaces which
            are packet-oriented."
 
        GROUP ifHCPacketGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are packet-oriented and for which the value of the
            corresponding instance of ifSpeed is greater than
            650,000,000 bits/second."
 
        GROUP ifTestGroup
        DESCRIPTION
            "This group is optional. Media-specific MIBs which require
            interface tests are strongly encouraged to use this group
            for invoking tests and reporting results. A medium specific
            MIB which has mandatory tests may make implementation of
 
            this group mandatory."
 
        GROUP ifRcvAddressGroup
        DESCRIPTION
            "The applicability of this group MUST be defined by the
            media-specific MIBs. Media-specific MIBs must define the
            exact meaning, use, and semantics of the addresses in this
            group."
 
        OBJECT ifLinkUpDownTrapEnable
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifPromiscuousMode
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifStackStatus
        SYNTAX INTEGER { active(1) } -- subset of RowStatus
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required, and only one of the six
            enumerated values for the RowStatus textual convention need
            be supported, specifically: active(1)."
 
        OBJECT ifAdminStatus
        SYNTAX INTEGER { up(1), down(2) }
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required, nor is support for the value
            testing(3)."
    ::= { ifCompliances 1 }
 
ifCompliance2 MODULE-COMPLIANCE
    STATUS deprecated
    DESCRIPTION
            "A compliance statement defined in a previous version of
            this MIB module, for SNMP entities which have network
            interfaces."
 
    MODULE -- this module
        MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2,
                           ifCounterDiscontinuityGroup }
 
        GROUP ifFixedLengthGroup
        DESCRIPTION
            "This group is mandatory for all network interfaces which
            are character-oriented or transmit data in fixed-length
            transmission units."
 
        GROUP ifHCFixedLengthGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are character-oriented or transmit data in fixed-
            length transmission units, and for which the value of the
            corresponding instance of ifSpeed is greater than 20,000,000
            bits/second."
 
        GROUP ifPacketGroup
        DESCRIPTION
            "This group is mandatory for all network interfaces which
            are packet-oriented."
 
        GROUP ifHCPacketGroup
        DESCRIPTION
            "This group is mandatory only for those network interfaces
            which are packet-oriented and for which the value of the
            corresponding instance of ifSpeed is greater than
            650,000,000 bits/second."
 
        GROUP ifRcvAddressGroup
        DESCRIPTION
            "The applicability of this group MUST be defined by the
            media-specific MIBs. Media-specific MIBs must define the
            exact meaning, use, and semantics of the addresses in this
            group."
 
        OBJECT ifLinkUpDownTrapEnable
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifPromiscuousMode
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
 
        OBJECT ifStackStatus
        SYNTAX INTEGER { active(1) } -- subset of RowStatus
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required, and only one of the six
            enumerated values for the RowStatus textual convention need
            be supported, specifically: active(1)."
 
        OBJECT ifAdminStatus
        SYNTAX INTEGER { up(1), down(2) }
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required, nor is support for the value
            testing(3)."
 
        OBJECT ifAlias
        MIN-ACCESS read-only
        DESCRIPTION
            "Write access is not required."
    ::= { ifCompliances 2 }
 
END