Public/Set-LMDevice.ps1
<# .SYNOPSIS Updates a LogicMonitor device configuration. .DESCRIPTION The Set-LMDevice function modifies an existing device in LogicMonitor, allowing updates to its name, display name, description, collector settings, and various other properties. .PARAMETER Id Specifies the ID of the device to modify. This parameter is mandatory when using the 'Id' parameter set. .PARAMETER Name Specifies the current name of the device. This parameter is mandatory when using the 'Name' parameter set. .PARAMETER NewName Specifies the new name for the device. .PARAMETER DisplayName Specifies the new display name for the device. .PARAMETER Description Specifies the new description for the device. .PARAMETER PreferredCollectorId Specifies the ID of the preferred collector for the device. .PARAMETER PreferredCollectorGroupId Specifies the ID of the preferred collector group for the device. .PARAMETER AutoBalancedCollectorGroupId Specifies the ID of the auto-balanced collector group for the device. .PARAMETER Properties Specifies a hashtable of custom properties for the device. .PARAMETER PropertiesMethod Specifies how to handle existing properties. Valid values are "Add", "Replace", or "Refresh". Default is "Replace". .PARAMETER HostGroupIds Specifies an array of host group IDs to associate with the device. .PARAMETER Link Specifies the URL link associated with the device. .PARAMETER DisableAlerting Specifies whether to disable alerting for the device. .PARAMETER EnableNetFlow Specifies whether to enable NetFlow for the device. .PARAMETER NetflowCollectorGroupId Specifies the ID of the NetFlow collector group. .PARAMETER NetflowCollectorId Specifies the ID of the NetFlow collector. .PARAMETER EnableLogCollector Specifies whether to enable log collection for the device. .PARAMETER LogCollectorGroupId Specifies the ID of the log collector group. .PARAMETER LogCollectorId Specifies the ID of the log collector. .EXAMPLE Set-LMDevice -Id 123 -NewName "UpdatedDevice" -Description "New description" Updates the device with ID 123 with a new name and description. .INPUTS You can pipe objects containing Id properties to this function. .OUTPUTS Returns a LogicMonitor.Device object containing the updated device information. .NOTES This function requires a valid LogicMonitor API authentication. #> Function Set-LMDevice { [CmdletBinding(SupportsShouldProcess, ConfirmImpact = 'None')] Param ( [Parameter(Mandatory, ParameterSetName = 'Id', ValueFromPipelineByPropertyName)] [String]$Id, [Parameter(Mandatory, ParameterSetName = 'Name')] [String]$Name, [String]$NewName, [String]$DisplayName, [String]$Description, [Nullable[Int]]$PreferredCollectorId, [Nullable[Int]]$PreferredCollectorGroupId, [Nullable[Int]]$AutoBalancedCollectorGroupId, [Hashtable]$Properties, [String[]]$HostGroupIds, #Dynamic group ids will be ignored, operation will replace all existing groups [ValidateSet("Add", "Replace", "Refresh")] # Add will append to existing prop, Replace will update existing props if specified and add new props, refresh will replace existing props with new [String]$PropertiesMethod = "Replace", [String]$Link, [Nullable[boolean]]$DisableAlerting, [Nullable[boolean]]$EnableNetFlow, [Nullable[Int]]$NetflowCollectorGroupId, [Nullable[Int]]$NetflowCollectorId, [Nullable[boolean]]$EnableLogCollector, [Nullable[Int]]$LogCollectorGroupId, [Nullable[Int]]$LogCollectorId ) #Check if we are logged in and have valid api creds Begin {} Process { If ($Script:LMAuth.Valid) { #Lookup ParentGroupName If ($Name) { $LookupResult = (Get-LMDevice -Name $Name).Id If (Test-LookupResult -Result $LookupResult -LookupString $Name) { return } $Id = $LookupResult } #Build custom props hashtable $customProperties = @() If ($Properties) { Foreach ($Key in $Properties.Keys) { $customProperties += @{name = $Key; value = $Properties[$Key] } } } #Build header and uri $ResourcePath = "/device/devices/$Id" If ($PSItem) { $Message = "Id: $Id | Name: $($PSItem.name) | DisplayName: $($PSItem.displayName)" } Elseif ($Name) { $Message = "Id: $Id | Name: $Name" } Else { $Message = "Id: $Id" } Try { $Data = @{ name = $NewName displayName = $DisplayName description = $Description disableAlerting = $DisableAlerting enableNetflow = $EnableNetFlow customProperties = $customProperties preferredCollectorId = $PreferredCollectorId preferredCollectorGroupId = $PreferredCollectorGroupId autoBalancedCollectorGroupId = $AutoBalancedCollectorGroupId link = $Link netflowCollectorGroupId = $NetflowCollectorGroupId netflowCollectorId = $NetflowCollectorId isPreferredLogCollectorConfigured = $EnableLogCollector logCollectorGroupId = $LogCollectorGroupId logCollectorId = $LogCollectorId hostGroupIds = $HostGroupIds -join "," } #Remove empty keys so we dont overwrite them @($Data.keys) | ForEach-Object { If ([string]::IsNullOrEmpty($Data[$_]) -and ($_ -notin @($MyInvocation.BoundParameters.Keys))) { $Data.Remove($_) } } $Data = ($Data | ConvertTo-Json) If ($PSCmdlet.ShouldProcess($Message, "Set Device")) { $Headers = New-LMHeader -Auth $Script:LMAuth -Method "PATCH" -ResourcePath $ResourcePath -Data $Data $Uri = "https://$($Script:LMAuth.Portal).logicmonitor.com/santaba/rest" + $ResourcePath + "?opType=$($PropertiesMethod.ToLower())" Resolve-LMDebugInfo -Url $Uri -Headers $Headers[0] -Command $MyInvocation -Payload $Data #Issue request $Response = Invoke-RestMethod -Uri $Uri -Method "PATCH" -Headers $Headers[0] -WebSession $Headers[1] -Body $Data Return (Add-ObjectTypeInfo -InputObject $Response -TypeName "LogicMonitor.Device" ) } } Catch [Exception] { $Proceed = Resolve-LMException -LMException $PSItem If (!$Proceed) { Return } } } Else { Write-Error "Please ensure you are logged in before running any commands, use Connect-LMAccount to login and try again." } } End {} } |